Project | YY-D-300-5 |
Output Power | 300W |
Input Voltage | 110V Product: 100Vac~135Vac 220V Product: 200Vac~240Vac Switch by toggle the Settings switch inside the product |
Input Voltage Range | 110V Product:100 Vac ~135Vac 220V Product:180 Vac ~264Vac |
Frequency range | 47HZ~63HZ |
Leakage Current | ≤0.25ma, @220Vac |
Maximum Input Current | 4A |
Inrush Current | ≤60A, @220Vac |
Efficiency(full load) | ≥80% |
Output Voltage | Comments |
5.0 Vdc | The power supply will stop working when the short circuit is triggered and it restart working after solving problem. |
Output Voltage | Comments |
5.0 Vdc | The power supply will stop working when the outputcurrent is more than 105~138% of rated current and it will restart working after solving problem. |
Output Voltage | Comments |
5.0 Vdc | The power supply will stop working when the temperature above the set value and it will restart working after solving problem. |
Output Voltage | Comments |
6.0 Vdc | The output will not exceed 6.0V when external factors trigger malfunction of output. That can avoid the damage to theloader of the power supply. |
Input To Output | 50Hz 3000Vac Ac file test 1 minute,Leakage current≤5mA |
Input To FG | 50Hz 2000Vac Ac file test 1 minute,Leakage current≤5mA |
Output To FG | 50Hz 500Vac Ac file test 1 minute,Leakage current≤5mA |
Input To Output | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Output To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature) |
Input To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Working Altitude: 0 to 3000m
Dimensions Outside dimension : L*W*H=220×117×32mmInput 110/220VacIf customer want the product to work at the environment of - 40℃, please indicate special requirement when customer order it.
Output Voltage And Current Specification Project | YY-D-300-5 |
Output Voltage | 5.0V |
Setting Accuracy (No load) | ±0.05V |
Output Rated Current | 60A |
Peak Current | 65A |
Line Regulation | ±0.5% |
Load Regulation | LOAD≤ 70%:±1%(Amount to:±0.05V)V LOAD> 70%:±2%(Amount to:±0.1V)V |
Delay Time | 220Vac Intput @ -40~-5℃ | 220Vac Intput @ ≥25℃ |
Output Voltage:5.0 Vdc | ≤6S | ≤3S |
- | - | - |
Output Voltage | Change Rate | Voltage Range | Load Change |
5.0 Vdc | 1~1.5A/uS | ≤±5% | @Min.to 50% load and 50% to max load |
- | - | - |
Output Voltage | 220Vac input & full load | Note |
5.0 Vdc | ≤50mS | The rise time is when voltages rise from 10% to 90% . |
Output Voltage | Ripple & Noise |
5.0 Vdc | 140mVp-p@25℃ |
240mVp-p@-25℃ |
Name | Function |
L L | The AC Input Line L |
N N | The AC Input Line N |
Earth Line |
Current conducted through the output terminal block should not exceed 20A, so do not overload test and work at that condition. Or the terminal block will be damaged from high temperature.
Name | Function |
V+ V+ V+ | Output DC positive pole |
V- V- V- | Output DC negative pole |