Project | YY-D-300-5 |
Normal output power | 300W |
Normal voltage range | 200 Vac ~240Vac |
Input voltage range | 176Vac ~264Vac |
Frequency range | 47HZ~63HZ |
Leakage Current | ≤0.25ma,@220Vac |
Max input AC current | 2A |
Inrush current | ≤60A,@220VAC |
Efficiency(full load) | ≥88% |
Output Voltage | Comments |
5.0 Vdc | The power supply will be stopped when the circuit is shorted and restart operating after eliminating malfunction. |
Output Voltage | Comments |
5.0 Vdc | The power supply will stop working when the output current is more than 105~138% of rated current and it will restart working after eliminating malfunction. |
Output Voltage | Comments |
5 Vdc | The power supply will stop working when the temperature above the set value and it will restart working after solving problem. |
Input To Output | 50Hz 3000Vac Ac file test 1 minute,Leakage current≤5mA |
Input To FG | 50Hz 2000Vac Ac file test 1 minute,Leakage current≤5mA |
Output To FG | 50Hz 500Vac Ac file test 1 minute,Leakage current≤5mA |
Input To Output | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Output To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature) |
Input To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Working Altitude: 0 to 3000m
Dimensions Outside dimension : L*W*H=215×87×30mm Project | YY-D-300-5 |
Output Voltage | 5.0V |
Setting Accuracy (No load) | ±0.05V |
Output Rated Current | 60A |
Peak Current | 65A |
Line Regulation | ±0.5% |
Load Regulation | Load≤70:±1%(Amount to:±0.05V)V Load>70:±2%(Amount to:±0.1V)V |
Delay Time | 220Vac Input @ -40~-5℃ | 220Vac Input @ ≥25℃ |
Output Voltage:5.0 Vdc | ≤6S | ≤3S |
- | - | - |
Output Voltage | Change Rate | Voltage Range | Load Change |
5.0 Vdc | 1~1.5A/uS | ≤±5% | @Min.to 50% load and 50% to max load |
- | - | - |
Output Voltage | 220Vac input & full load | Note |
5.0 Vdc | ≤50mS | The rise time is when voltages rise from 10% to 90%. |
Output Voltage | Ripple & Noise |
5.0 Vdc | 140mVp-p@25℃ |
240mVp-p@-25℃ |
Name | Function |
L L | The AC Input Line L |
N N | The AC Input Line N |
Earth Line |
Name | Function |
V+ V+ V+ | Output DC positive pole |
V- V- V- | Output DC negative pole |
The power supply must work at the condition of insulation and make sure the terminal post of cable is insulation. Besides, make sure the product is grounded well and forbid touching the cabinet to avoid scalding hand.