Project | YY-C-50-5 C Series |
Normal output power | 50W |
Normal voltage range | 200 Vac ~240Vac |
Input voltage range | 176Vac ~264Vac |
Frequency range | 47HZ~63HZ |
Leakage Current | ≤0.25ma,@220Vac |
Max input AC current | 0.5A |
Inrush current | ≤15A,@220VAC |
Efficiency(full load) | ≥82% (@220V) |
Output Voltage | Comments |
5.0 Vdc | Output will be stopped when the circuit is shorted and restart operating after eliminating malfunction. |
Output Voltage | Comments |
5.0 Vdc | Output will stop working when the output current is more than 105~125% of rated current and it will restart working after eliminating malfunction. |
Output Voltage | Comments |
5.0 Vdc | Output will stop working when the temperature above the set value and it will restart working after eliminating malfunction. |
Input To Output | 50Hz 2750Vac Ac file test 1 minute,Leakage current≤5mA |
Input To FG | 50Hz 1500Vac Ac file test 1 minute,Leakage current≤5mA |
Input To Output | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Output To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature) |
Input To FG | DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature) |
Working Altitude: 0 to 3000m
Dimensions Outside dimension : L*W*H=115×70×26mmIf the product has long been working at the environment - 40℃, please indicate your special request.
Output Voltage And Current Regulation Project | YY-C-50-5 C Series |
Output Voltage | 5.0V |
Setting Accuracy (No load) | ±0.05V |
Output Rated Current | 10A |
Peak Current | 12A |
Regulation | ±2% |
Delay Time | 220Vac Input @ -40~-5℃ | 220Vac Input @ ≥25℃ |
Output Voltage:5.0 Vdc | ≤6S | ≤5S |
- | - | - |
Output Voltage | Change Rate | Voltage Range | Load Change |
5.0 Vdc | 1~1.5A/uS | ≤±5% | @Min.to 50% load and 50% to max load |
- | - | - |
Output Voltage | 220Vac input & full load | Note |
5.0 Vdc | ≤50mS | The rise time measured is when the output voltages rise from 10% to 90% of specified output voltage Vout observed on the channel waveform. |
- | - |
Output Voltage | Ripple & Noise |
5.0 Vdc | 150mVp-p@25℃ |
270mVp-p@-25℃ |
Name | Function |
L | The AC Input Line L |
N | The AC Input Line N |
Earth Line |
Name | Function |
V+ | Output DC positive pole |
V- | Output DC negative pole |
The power supply must work at the condition of insulation and terminal post of cable have to go through the insulation treatment. Besides, make sure the product is grounded well and forbid touching the cabinet in order to avoid scalding hand.
Output current and voltage curve