Youyi YY-C-50-5 C-Series 5V 10A LED Power Supply

The product which is AC-DC constant voltage power supply can drive the industrial equipment, like LED display. Its characteristics are that it have a high efficiency, small capacity, a stable output and a high reliability. It also have various protection function, such as short circuit protection, over temperature protection and so on.

Products Details

A. Shock: 49m/s2(5G),11ms,once each X,Y and Z axis. B. Vibration: 10-55Hz,19.6m/s2(2G),20 minutes each along X,Y and Z axis.Input Electrical Characteristics
Project YY-C-50-5   C Series

Normal output power

50W

Normal voltage range

200 Vac ~240Vac
Input voltage range 176Vac ~264Vac

Frequency range

47HZ~63HZ

Leakage Current

≤0.25ma,@220Vac

Max input AC current

0.5A

Inrush current

≤15A,@220VAC
Efficiency(full load) ≥82% (@220V)
Operate temperature rating CurveOutput Short Circuit Protection

Output Voltage

Comments

 5.0 Vdc

Output will be stopped when the circuit is shorted and restart operating after eliminating malfunction.
  Output Over Load Protection

Output Voltage

Comments

  5.0 Vdc Output will stop working when the output current is more than 105~125% of rated current and it will restart working after eliminating malfunction.
  Over Temperature Protection

Output Voltage

Comments

 5.0 Vdc

Output will stop working when the temperature above the set value and it will restart working after eliminating malfunction.

Dielectric Strength

Input To Output

50Hz 2750Vac Ac file test 1 minute,Leakage current≤5mA 

Input To FG

50Hz 1500Vac Ac file test 1 minute,Leakage current≤5mA 

  Insulation Resistance

Input To Output

DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature)

Output To FG

DC 500V The minimum insulation resistance must be no less than 10MΩ (at room temperature)

Input To FG

DC 500V The minimum insulation resistance must be no less than 10MΩ(at room temperature)

Environment Temperature Working Temperature:-25℃~+60℃
Products are able to start and work at -40℃. If the product has long been working at the environment - 40℃, please indicate your special request.
  Storage Temperature:-40℃ ~ +70℃   Humidity Working Humidity: Relative humidity is from 15RH to 90RH. Storage Humidity: Relative humidity is from 5RH to 95RH.   Altitude

Working Altitude: 0 to 3000m

Dimensions Outside dimension : L*W*H=115×70×26mm
Operate voltage rating Cuidline

If the product has long been working at the environment - 40℃, please indicate your special request.

Output Voltage And Current Regulation

Project

 YY-C-50-5  C Series

Output Voltage

 5.0V

Setting Accuracy

(No load)

 ±0.05V

Output Rated Current

 10A

Peak Current

12A

Regulation

 ±2%

  Power on Delay Time

Delay Time

220Vac Input @ -40~-5℃

220Vac Input @ ≥25℃

Output Voltage:5.0 Vdc

≤6S

≤5S

-

-

-

  Output Transient Response

Output Voltage

Change Rate

Voltage Range Load Change
5.0 Vdc

1~1.5A/uS

≤±5%

@Min.to 50% load and 50% to max load

-

-

-

  DC Output Voltage Rise Time

Output Voltage

220Vac input & full load

Note

 5.0 Vdc   ≤50mS  The rise time measured is when the output voltages rise from 10% to 90% of specified output voltage Vout observed on the channel waveform.
- -
  DC Output Ripple & Noise

Output Voltage

Ripple & Noise

5.0 Vdc

150mVp-p@25℃

270mVp-p@-25℃

Measure Methods A. Ripple & Noise test:Ripple & Noise bandwidth is set to 20mHZ. B. Use a 0.1uf ceramic capacitor in parallel with a 10uf electrolytic capacitor at output connector terminals for ripple & noise measurements.  Natural cooling
 
Specific Cautions A. The product should be suspended in air or installed on the face of metal when it is assembled, and be avoided to place on the face of non-conducting heat materials such as, plastics, board and so on. B. The space between each module should be exceeded 5cm in order to avoid affecting cooling of power supply.The MTBF shall be at least 50,000 hours at 25℃ at the condition of full loading.Table 1 : Input 5 pin terminal block (pitch 9.5mm)

Name

Function

L

The AC Input Line L

N

The AC Input Line N

 Earth Line

 

Name

Function

V+

Output DC positive pole

V- 

Output DC negative pole

Current through the output terminal block should not exceed 10A, so never overload test and work in that kind of condition. Or the terminal block will be damaged because of high temperature.

The power supply must work at the condition of insulation and terminal post of cable have to go through the insulation treatment. Besides, make sure the product is grounded well and forbid touching the cabinet in order to avoid scalding hand.

Output current and voltage curve
The figure below is mounting hole position
Unit:mm

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours