Output Power (W) | Rated Input Voltage (Vac) | Rated Output Voltage (Vdc) | Output Current Range (A) | Precision | Ripple and Noise (mVp-p) |
300 | 110/220(±20%) | +5.0 | 0-60.0 | ±2% | ≤150 |
NO | ITEM | SPECIFICATION | UNIT | NOTE |
1.1 | INPUT VOLTAGE | 200 ~ 240 | Vac |
|
1.2 | INPUT FREQUENCY | 47 ~ 63 | Hz |
|
1.3 | EFFICIENC | ≥80(Vin=220Vac) | % | full-load output in normal temperature |
1.5 | POWER FACTOR | ≥0.52 |
| full-load output in rated input voltage |
1.6 | MAX INPUT CURRENT | ≤3.0 | A |
|
1.7 | STARTING SURGE CURRENT | ≤60 | A | cold state test |
NO | ITEM | SPECIFICATION | UNIT | NOTE |
2.1 | RATED OUTPUT VOLTAGE | +5 | Vdc |
|
2.2 | OUTPUT CURRENT | 0 ~60.0 | A |
|
2.3 | OUTPUT VOLTAGE ADJ RANGE | 4.6~ 5.4 | Vdc |
|
2.4 | VOLTAGE REGULATION RATE | ±1% | Vo | Meanwhile test in light load, half load, full load without mixing |
2.5 | LOAD REGULATION RATE | ±1% | Vo | |
2.6 | VOLTAGE REGULATION ACCURACY | ±2% | Vo | |
2.7 | RIPPLE & NOISE | ≤150 | mVp-p | rated input, full load output, 20MHz bandwidth, 47μF capacitor paralleled in load end |
2.8 | BOOT OUTPUT DELAY | ≤3000 | ms |
|
2.9 | OUTPUT HOLD TIME | ≥10 | ms | Vin=220Vac test |
2.1 | OUTPUT VOLTAGE RISE PERIOD | ≤50 | ms |
|
2.11 | SWITCHING OVERSHOOT | ±5% | Vo | test condition: full load, mode CR |
2.12 | DYNAMIC OUTPUT | The voltage change of less than + 5% VO ;Dynamic response time≤250us | Vo | Load 25%-50% , 50%-75% |
NO | ITEM | SPECIFICATION | UNIT | NOTE |
3.1 | INPUT UNDER VOLTAGE PROTECTION | 140~175 | Vac | Test condition: full load |
3.2 | INPUT UNDER VOLTAGE PROTECTION POINT | 160-180 | Vac | |
3.2 | OUTPUT CURRENT LIMITING PROTECTION POINT | 66-90 | A | HI-CUP burp self recovery, avoiding the damage power long after short circuit |
3.3 | OUTPUT SHORT CIRCUIT PROTECTION POINT | >60.0 | A |
NO | ITEM | SPECIFICATION | UNIT | NOTE |
4.1 | MTBF | ≥40,000 | H |
|
4.2 | LEAKAGE CURRENT | <1.0mA(Vin=220Vac) | GB8898-2001 9.1.1 test method |
Item | Description | Tech Spec | Remark | |
1 | Electric Strength | Input to output | 3000Vac/10mA/1min | No arcing, no breakdown |
2 | Electric Strength | Input to ground | 1500Vac/10mA/1min | No arcing, no breakdown |
3 | Electric Strength | Output to ground | 500Vac/10mA/1min | No arcing, no breakdown |
ITEM | SPECIFICATION | UNIT | NOTE |
WORK TEMPERATURE | -30 ~ +60 | ℃ |
|
STORAGE TEMPERATURE | -40 ~ +80 | ℃ |
|
RELATIVE HUMIDITY | 10 ~ 60 | % |
|
COOLING TYPE | self cooling |
|
|
ATMOSPHERIC PRESSURE | 80 ~ 106 | Kpa |
|
HEIGHT ABOVE SEA LEVEL | 2000 | m |
-
- 1)Physical Dimension L * W * H = 212×81.5×30.5±0.5 2)Installation hole Measurement
Temperature vs Load Curve
Input Voltage vs Load Curve
Efficiency vs Load Curve
1)In installation, the power must be safe and insulative ,safe distance to metal frame in every side Must be ≧8mm. If it is less than 8mm, a PVC gasket thickness ≧1mm is required to reinforce insulation. 2) Direct touching cooling plate by hand is prohibited. 3) A bolt diameter is ≦8mm when installing PCB plate. 4)Need a mat outside L285mm * W130mm * H3mm aluminum as an auxiliary hea