Wholesales CZCL A-200AF-5 Slim LED Screen Power Supply Switch Chuanglian 5V 40A 200W

A-200AF-5X3 is Led display power supply without fans. The input voltage rang is 176~264VAC and output voltages are 2.8V、3.3V、3.8V、4.2V、4.5V、5V. It can be applied to Led display、LED indicator light and other Led display fileds. This series product is ultra-thin design, with a height of only 30mm, and can adapt to a variety of box size requirements. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work of this series of products.

Products Details

⬤Standard slim model,height 30mm ⬤20~+70C working temperature (refer to derating curve) ⬤Protections: short circuit/overload ⬤100% full load burn-in test ⬤High efficiency, High reliability ⬤2 years warrantyA-200AF-5X3 is Led display power supply without fans. The input voltage rang is 176~264VAC and output voltages are 2.8V、3.3V、3.8V、4.2V、4.5V、5V. It can be applied to Led display、LED indicator light and other Led display fileds. This series product is ultra-thin design, with a height of only 30mm, and can adapt to a variety of box size requirements. Super high efficiency, compact shell design and good heat dissipation ensure the long-term stable work of this series of products.

Model

A-200AF-2.8X3 A-200AF-3.3X3 A-200AF-3.8X3 A-200AF-4.2X3 A-200AF-4.5X3 A-200AF-5X3

Input

Voltage range

176~264VAC

 

Input current

230VAC/2.5A

 

Efficiency

≥81%

≥82%

≥83%

≥84%

≥85%

≥86%

 

Frequency range

47~63HZ

 

Leakage current

<3.5mA/240VAC

 

Inrush current

60A/230VAC

Output

DC voltage

2.8V

3.3V

3.8V

4.2V

4.5V

5V

 

Rated current

40A

40A

40A

40A

40A

40A

 

Power

112W

32W

152W

160W

180W

200W

 

Voltage

adj.range

/

/

/

/

/

/

 

Ripple and

noise

170mVp-p

170mVp-p

170mVp-p

170mVp-p

170mVp-p

170mVp-p

 

Set up,rise

time

2500ms,50ms/220VAC 100% load

 

Hold up time

10ms/220VAC 100% load

 

Line

regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

 

Load

regulation

± 1.0%

± 1.0%

± 1.0%

± 1.0%

± 1.0%

± 1.0%

 

Output Voltage

Accuracy

±3.0%

±3.0%

±3.0%

±3.0%

±3.0%

±3.0%

EMC

EMS

Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11

 

Harmonic

current

Design refer to:GB17625.1;EN61000-3-2,-3

 

EMC

Design refer to:EN55022,Class A

Safety

Safety

standard

Design refer to:GB4943/UL1012

 

Withstand

voltage

I/P-O/P:3KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA

each testing time:1min

 

Isolation

resistance

I/P-O/P: 50M ohms;   I/P-Case:50M ohms;   O/P-Case:50M ohms

Protecti on

Over Voltage

 

 

Over load

110~165% rated  Hiccup mode, recovers automatically after fault condition is removed

 

Over

Temperature

/

 

Short circuit

Power supply protection after short circuit, and output can be recovered automatically after eliminating short circuit

Envirome nt

Working

temperature and

humidity

-20~70℃; 20%~95%RH  no condensing (refer to derating curve)
 

Storage

temperature

and humidity

-30℃~85℃; 10%~95%RH nomondensing
 

Vibration

Frequency range 10 ~ 500Hz,acceleration 2G, each sweep cycle for 10min, 6 sweep cycles along X, y, Z axis
 

Shock

Acceleration: 20g, duration: 11ms, 3 impacts along X, y, Z axis
 

Altitude

2000mtrs (for every 100 m higher than 2000 m, the ambient temperature decreases by 0.6 ℃)

Reliability

MTBF

25℃:250000Hrs, MIL-217 Method

Others

Size

190*81*30 mm (L*W*H)

 

Packing

0.36Kg/piece,30pieces/carton,11KG/carton

 

Cooling mode

☑ Free air     □  Fan

 

Extension mode

 three proofings  ☑ terminal cover  □ Low temperature start (-40℃)   others

Remarks

*In order to extend the lifetime, it is recommended to configure the load more than 30% of the remainingallowance. For example: the power of the device requires 100W, then use the power of not less than 130W. *Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. *All electrical performance tests are performed at 25 C. *When the product is used in full load, the aluminum plate with an area of 400 * 400 * 3mm shall be added for auxiliary heat dissipation. *The power supply is a part of the components of the equipment system. All EMC tests are conducted by installing the sample on the metal plate. The power supply shall be confirmed with the terminal equipment for electromagnetic compatibility.
    1. 1、When installing, please follow the mechanical size and installation method. 2、Before commissioning, please check and proofread the connections on the terminals to make sure that the input and output, AC and DC, positive and negative poles, voltage and current values are correct, to prevent the occurrence of reverse connection errors and to avoid damage to power supply and user equipment. 3、Please use the multimeter to measure whether the fire line, zero line and ground line are short-circuited and whether the output terminal is short-circuited before power is turned on. 4、Do not exceed the nominal value of the power supply in use, so as to avoid affecting the reliability of the product. If you need to change the output parameters of the power supply, please consult the technical department of our company before using the power supply to ensure the effectiveness and reliability of the use. 5、To ensure safety and reduce interference, ensure reliable grounding of grounding end (grounding wire>AWG18#). 6、If the power supply fails, please do not repair it without authorization. Please contact our customer service department as soon as possible.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours