Model | A-300AB-5 | ||||||
Output | DC voltage | 5V | |||||
| Rated current | 60A | |||||
| Current range | 0~60A | |||||
| Rated power | 300W | |||||
| Ripple & Noise | 200mVp-p | |||||
| Tage regulation ran | 4.5~5.5V | |||||
| Voltage accuracy | ±2.0% | |||||
| Line adjustment rate | ±0.5% | |||||
| Load adjustment rate | ±2% | |||||
Rise | 3000ms,50ms/230VAC 100% load | ||||||
Hold up time (Typ) | 20ms/230VAC 100% load | ||||||
Input | Voltage range | 180~264VAC | |||||
Frenquency range | 47~63HZ | ||||||
PFC (Typ) | PF≥0.5 | ||||||
Efficiency(Typ) | ≥86% |
|
|
|
| ||
Alterna ting | 15VAC | / |
|
|
|
| |
| 30VAC | 3.1A |
|
|
|
| |
Rush current (Typ) | 60A/230VAC | ||||||
Leakage current | <1mA/230VAC | ||||||
Protec tion | Over load | 110~150% rated | |||||
| Short circuit | shut off, AC recycle to re-start | |||||
| Over voltage | voltage limited 110%~140% of rated voltage | |||||
| Over temp. | / | |||||
Environment
| Working temp. | -20℃~+50℃ (AC 230V) (Refer to temperature derating curve) | |||||
Working humidity | 20~90%RH no condensing | ||||||
Storage Temp. | -30~+85℃ | ||||||
Storage humidity | 10~95%RH no condensing | ||||||
Temp. coefficiency | ±0.03%/℃ (0~50℃) | ||||||
Vibration resistance | 10~500Hz,2G,10min/cycle,X、Y、Z 60min in each direction | ||||||
Safety Standards | Design refer to GB4943,UL60950-1,EN60950-1 | ||||||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
solation resistance | I/P-O/P、I/P-FG、O/P-FG:>50MΩ/500VDC/25℃/70%RH | ||||||
EMC | Design refer to GB9254 EN55022,Class A | ||||||
Harmonic Current | Design refer to GB17625.1;EN61000-3-2,-3 | ||||||
EMS | Design refer to EN55024 ;EN61000-4-2,3,4,5,6,8,11 | ||||||
Others | Lifetime | 100,000 hours (25℃) | |||||
| Size | 212*81.5*31.1 (L*W*H) | |||||
| package | 0.55Kg/pcs | |||||
Remarks | *In order to extend the lifetime, it is recommended to configure the load no more than 30% of the remaining allowance. For example : the power of the device requires 100W, then use the power of less than 130W.*Ripple test method : 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. |
Pin No | Assignment | Pin No | Assignment |
1~2 | AC/N | 6~8 | DC output(-V) |
3~4 | AC/L | 9~11 | DC output(+V) |
5 | FG |
|